Assessment Year | 1989 |
---|---|
Principal Product | POLYESTER & NYLON YARNS |
NAICS |
n/a
|
SIC | 2269: Finishers of Textiles, Not elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
n/a
|
Annual Production | 5,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $995,174 | 21,648,007 |
kWh
|
$0.046 |
Natural Gas | $286,642 | 81,688 |
MMBtu
|
$3.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $80,507 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $68,385 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2136: Install / repair insulation on steam lines | $25,781 | $2,304 | - |
$25,781
-
MMBtu
|
- | |
02 | 2.2511: Insulate bare equipment | $8,728 | $2,428 | - |
$8,728
-
MMBtu
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $19,212 | - |
$19,212
417,644
kWh
|
- | - | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $6,433 | $17,200 | - |
$6,433
-
MMBtu
|
- | |
05 | 2.2135: Repair and eliminate steam leaks | $3,364 | $240 | - |
$3,364
-
MMBtu
|
- | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,146 | $800 | - |
$2,146
-
MMBtu
|
- | |
07 | 2.2122: Install / repair insulation on condensate lines | $1,960 | $200 | - |
$1,960
-
MMBtu
|
- | |
08 | 2.7123: Keep lamps and reflectors clean | $3,394 | $11,235 |
$3,074
66,823
kWh
|
- | $320 | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,489 | $3,870 |
$9,489
206,331
kWh
|
- | - | |
TOTAL RECOMMENDED | $80,507 | $38,277 |
$31,775
690,798
kWh
|
$48,412
-
MMBtu
|
$320 | ||
TOTAL IMPLEMENTED | $68,385 | $24,614 |
$28,701
623,975
kWh
|
$39,684
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs