| Assessment Year | 1989 | 
|---|---|
| Principal Product | FIBERGLASS PLASTICS | 
| NAICS | 
                             n/a 
                     | 
    
| SIC | 3089: Plastics Products, Not Elsewhere Classified | 
| Sales Range | $10 M  to 50M  | 
    
| # of Employees | 250 | 
| Plant Area | 
                             n/a 
                     | 
    
| Annual Production | 7,600
             
ton
 
         | 
    
| Production Hrs. Annual | 6,240
             
hrs
 
         | 
    
| Location (State) | Virginia | 
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $191,730 | 3,973,916 | 
             
kWh
 
         | 
        $0.048 | 
| Natural Gas | $69,128 | 19,512 | 
             
MMBtu
 
         | 
        $3.54 | 
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $59,986 | 
             See individual recommendations below 
            *Non-energy impacts included in savings.
         | 
    ||
| IMPLEMENTED SAVINGS* | $59,986 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | 
|---|---|---|---|---|---|---|
| 01 | 2.4237: Substitute compressed air cooling with water or air cooling | $24,816 | $13,460 | 
                        $24,816
                                                     516,999
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 02 | 2.2135: Repair and eliminate steam leaks | $5,334 | $600 | - | 
                        $5,334
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 03 | 2.2163: Use minimum steam operating pressure | $2,783 | - | - | 
                        $2,783
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 04 | 2.7314: Reduce ventilation air | $10,059 | $3,100 | 
                        $10,059
                                                     209,555
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 05 | 2.2437: Recover waste heat from equipment | $2,475 | $3,050 | - | 
                        $2,475
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    |
| 06 | 2.2511: Insulate bare equipment | $7,555 | $536 | 
                        $7,555
                                                     157,386
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,305 | $660 | 
                        $4,305
                                                     89,683
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| 08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,659 | - | 
                        $2,659
                                                     55,393
                                 
                                            
kWh
 
                             | 
                                                                                - | |
| TOTAL RECOMMENDED | $59,986 | $21,406 | 
                        $49,394
                                                     1,029,016
                                 
                                            
kWh
 
                             | 
                                                                                
                        $10,592
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| TOTAL IMPLEMENTED | $59,986 | $21,406 | 
                        $49,394
                                                     1,029,016
                                 
                                            
kWh
 
                             | 
                                                                                
                        $10,592
                                                     -
                                 
                                            
MMBtu
 
                             | 
                                    ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs