Assessment Year | 1988 |
---|---|
Principal Product | ASPHALT HOT MIX EQUIPMENT |
NAICS |
n/a
|
SIC | 3531: Construction Machinery and Equipment |
Sales Range | $50 M to 100M |
# of Employees | 470 |
Plant Area |
n/a
|
Annual Production | 400,000
ton
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $262,253 | 4,635,991 |
kWh
|
$0.057 |
Natural Gas | $62,978 | 12,395 |
MMBtu
|
$5.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,341 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $43,341 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7231: Use radiant heater for spot heating | $17,070 | $34,560 | - |
$17,070
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $9,024 | $8,980 |
$4,210
73,857
kWh
|
$4,814
-
MMBtu
|
|
03 | 2.7123: Keep lamps and reflectors clean | $12,279 | $14,384 |
$12,279
215,416
kWh
|
- | |
04 | 2.7226: Use computer programs to optimize hvac performance | $2,846 | $6,850 | - |
$2,846
-
MMBtu
|
|
05 | 2.4312: Improve lubrication practices | $1,370 | $1,200 |
$1,370
24,033
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $752 | $150 |
$752
13,189
kWh
|
- | |
TOTAL RECOMMENDED | $43,341 | $66,124 |
$18,611
326,495
kWh
|
$24,730
-
MMBtu
|
||
TOTAL IMPLEMENTED | $43,341 | $66,124 |
$18,611
326,495
kWh
|
$24,730
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs