| Assessment Year | 1987 |
|---|---|
| Principal Product | COSMETIC PACKAGING |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 440 |
| Plant Area |
n/a
|
| Annual Production | 6,000,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $556,440 | 11,573,857 |
kWh
|
$0.048 |
| Natural Gas | $12,069 | 2,444 |
MMBtu
|
$4.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,159 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,261 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $10,649 | $470 |
$10,649
221,864
kWh
|
- | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $8,961 | $2,175 |
$8,961
186,694
kWh
|
- | |
| 03 | 2.7221: Lower temperature during the winter season and vice-versa | $6,823 | $900 |
$6,823
142,145
kWh
|
- | |
| 04 | 2.4312: Improve lubrication practices | $4,249 | $1,290 |
$4,249
88,511
kWh
|
- | |
| 05 | 2.6214: Shut off pilots in standby equipment | $1,029 | - | - |
$1,029
-
MMBtu
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,448 | $1,200 |
$2,448
50,996
kWh
|
- | |
| TOTAL RECOMMENDED | $34,159 | $6,035 |
$33,130
690,210
kWh
|
$1,029
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $19,261 | $4,275 |
$18,232
379,835
kWh
|
$1,029
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs