Assessment Year | 1985 |
---|---|
Principal Product | RESCREENED JEANS |
NAICS |
n/a
|
SIC | 2325: Men's and Boys' Separate Trousers and Slacks |
Sales Range | $50 M to 100M |
# of Employees | 164 |
Plant Area |
n/a
|
Annual Production | 8,500,000
pieces
|
Production Hrs. Annual | 3,600
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,177 | 551,876 |
kWh
|
$0.073 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,139 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,755 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $5,755 | - |
$5,755
78,839
kWh
|
|
02 | 2.2136: Install / repair insulation on steam lines | $1,155 | $300 |
$1,155
15,533
kWh
|
|
03 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $696 | $200 |
$696
9,672
kWh
|
|
04 | 2.2511: Insulate bare equipment | $533 | $300 |
$533
7,327
kWh
|
|
TOTAL RECOMMENDED | $8,139 | $800 |
$8,139
111,371
kWh
|
||
TOTAL IMPLEMENTED | $5,755 | - |
$5,755
78,839
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs