| Assessment Year | 1985 |
|---|---|
| Principal Product | GAS RANGE BURNERS |
| NAICS |
n/a
|
| SIC | 3469: Metal Stampings, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 220 |
| Plant Area |
n/a
|
| Annual Production | 6,000,000
pieces
|
| Production Hrs. Annual | 4,375
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $92,851 | 1,768,757 |
kWh
|
$0.052 |
| Natural Gas | $22,305 | 3,683 |
MMBtu
|
$6.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,669 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,669 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.5194: Redesign process | $8,108 | $2,000 |
$8,108
155,920
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,753 | $135 |
$1,753
33,705
kWh
|
|
| 03 | 2.2511: Insulate bare equipment | $808 | $500 |
$808
15,533
kWh
|
|
| TOTAL RECOMMENDED | $10,669 | $2,635 |
$10,669
205,158
kWh
|
||
| TOTAL IMPLEMENTED | $10,669 | $2,635 |
$10,669
205,158
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs