Assessment Year | 1985 |
---|---|
Principal Product | WARMUP SUITS |
NAICS |
n/a
|
SIC | 2339: Women's, Misses', and Juniors' Outerwear, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 250,000
pieces
|
Production Hrs. Annual | 2,142
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $13,755 | 249,121 |
kWh
|
$0.055 |
Natural Gas | $6,929 | 1,116 |
MMBtu
|
$6.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,128 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $227 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $1,752 | - |
$1,752
31,653
kWh
|
- | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $149 | $1,000 | - |
$149
-
MMBtu
|
|
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $162 | - |
$162
2,931
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $65 | - |
$65
1,172
kWh
|
- | |
TOTAL RECOMMENDED | $2,128 | $1,000 |
$1,979
35,756
kWh
|
$149
-
MMBtu
|
||
TOTAL IMPLEMENTED | $227 | - |
$227
4,103
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs