| Assessment Year | 1987 |
|---|---|
| Principal Product | MOLDED PLASTIC PARTS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 3,500,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $97,369 | 2,092,907 |
kWh
|
$0.047 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,344 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,464 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $2,880 | $3,000 |
$2,880
97,304
kWh
|
|
| 02 | 2.3212: Optimize plant power factor | $6,830 | $10,000 |
$6,830
-
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $950 | $755 |
$950
24,912
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $684 | $97 |
$684
18,171
kWh
|
|
| TOTAL RECOMMENDED | $11,344 | $13,852 |
$11,344
140,387
kWh
|
||
| TOTAL IMPLEMENTED | $8,464 | $10,852 |
$8,464
43,083
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs