| Assessment Year | 1984 |
|---|---|
| Principal Product | VACUUM CLEANERS |
| NAICS |
n/a
|
| SIC | 3635: Household Vacuum Cleaners |
| Sales Range | $50 M to 100M |
| # of Employees | 350 |
| Plant Area |
n/a
|
| Annual Production | 400,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $406,636 | 8,512,017 |
kWh
|
$0.048 |
| Natural Gas | $106,021 | 23,931 |
MMBtu
|
$4.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,541 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,186 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $3,564 | $4,000 | - |
$3,564
-
MMBtu
|
|
| 02 | 2.6232: Install set-back timers | $8,300 | - |
$8,300
173,212
kWh
|
- | |
| 03 | 2.2514: Cover open tanks | $1,096 | $75 | - |
$1,096
-
MMBtu
|
|
| 04 | 2.2514: Cover open tanks | $273 | $75 | - |
$273
-
MMBtu
|
|
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $774 | - |
$774
16,120
kWh
|
- | |
| 06 | 2.2511: Insulate bare equipment | $422 | $53 |
$422
8,792
kWh
|
- | |
| 07 | 2.6212: Turn off equipment during breaks, reduce operating time | $112 | - |
$112
2,345
kWh
|
- | |
| TOTAL RECOMMENDED | $14,541 | $4,203 |
$9,608
200,469
kWh
|
$4,933
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $9,186 | - |
$9,186
191,677
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs