Assessment Year | 1984 |
---|---|
Principal Product | JACKETS & OUTERWEAR |
NAICS |
n/a
|
SIC | 2337: Women's, Misses', and Juniors' Suits, Skirts, and Coats |
Sales Range | $5 M to 10M |
# of Employees | 310 |
Plant Area |
n/a
|
Annual Production | 1,300,000
pieces
|
Production Hrs. Annual | 2,285
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $97,579 | 1,594,373 |
kWh
|
$0.061 |
Natural Gas | $17,813 | 3,390 |
MMBtu
|
$5.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,200 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,590 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $5,160 | $10 |
$5,160
128,957
kWh
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,336 | $2,325 |
$1,336
33,411
kWh
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $610 | $2,500 |
$610
15,240
kWh
|
- | |
04 | 2.2122: Install / repair insulation on condensate lines | $94 | $45 | - |
$94
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,200 | $4,880 |
$7,106
177,608
kWh
|
$94
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,590 | $2,380 |
$6,496
162,368
kWh
|
$94
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs