Assessment Year 1983
Principal Product CRUSHED ROCK
NAICS
n/a
SIC 3281: Cut Stone and Stone Products
Sales Range $1
M
to 5
M
# of Employees 18
Plant Area
n/a
Annual Production 800,000
ton
Production Hrs. Annual 2,000
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $296,897 2,968,933
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,620 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.3212: Optimize plant power factor $260 $3,200 $260
3,810
kWh
02 2.5121: Redesign flow to minimize mass transfer length $360 - $360
5,862
kWh
03 2.6212: Turn off equipment during breaks, reduce operating time $6,000 $2,000 $6,000
199,297
kWh
TOTAL RECOMMENDED $6,620 $5,200 $6,620
208,969
kWh
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs