Assessment Year | 1983 |
---|---|
Principal Product | TREATED WOOD PRODUCTS |
NAICS |
n/a
|
SIC | 2491: Wood Preserving |
Sales Range | $10 M to 50M |
# of Employees | 54 |
Plant Area |
n/a
|
Annual Production | 500,000
ton
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,446 | 1,595,545 |
kWh
|
$0.067 |
Natural Gas | $95,004 | 21,878 |
MMBtu
|
$4.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,517 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,517 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $8,400 | $5,000 |
$8,400
-
kWh
|
- | |
02 | 2.2511: Insulate bare equipment | $2,291 | $5,700 | - |
$2,291
-
MMBtu
|
|
03 | 2.9112: Use solar heat to heat water | $826 | $24,000 |
$826
27,257
kWh
|
- | |
TOTAL RECOMMENDED | $11,517 | $34,700 |
$9,226
27,257
kWh
|
$2,291
-
MMBtu
|
||
TOTAL IMPLEMENTED | $11,517 | $34,700 |
$9,226
27,257
kWh
|
$2,291
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs