Assessment Year | 1983 |
---|---|
Principal Product | GRAY IRON CASTING |
NAICS |
n/a
|
SIC | 3321: Gray and Ductile Iron Foundries |
Sales Range | $1 M to 5M |
# of Employees | 65 |
Plant Area |
n/a
|
Annual Production | 300
ton
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,657 | 908,558 |
kWh
|
$0.054 |
Natural Gas | $28,581 | 6,636 |
MMBtu
|
$4.31 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,462 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,300 | $5,000 |
$4,300
67,409
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $1,612 | $2,500 | - |
$1,612
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $50 | $200 |
$50
2,052
kWh
|
- | |
04 | 2.7492: Use proper thickness of insulation on building envelope | $4,500 | $1,500 | - |
$4,500
-
MMBtu
|
|
TOTAL RECOMMENDED | $10,462 | $9,200 |
$4,350
69,461
kWh
|
$6,112
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs