Assessment Year 1982
Principal Product SIGNS, OIL WELL EQUIPMENT
NAICS
n/a
SIC 3993: Signs and Advertising Specialties
Sales Range $50
M
to 100
M
# of Employees 300
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 4,420
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $208,130 4,143,025
kWh
Natural Gas $104,505 26,440
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,136 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $440 - $440
14,654
kWh
02 2.7111: Reduce illumination to minimum necessary levels $246 - $246
8,206
kWh
03 2.2511: Insulate bare equipment $9,900 $10,000 $9,900
330,012
kWh
04 2.7121: Utilize daylight whenever possible in lieu of artificial light $17,550 $50,000 $17,550
584,994
kWh
TOTAL RECOMMENDED $28,136 $60,000 $28,136
937,866
kWh
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs