| Assessment Year | 1982 |
|---|---|
| Principal Product | HUMIDIFIERS AND FANS |
| NAICS |
n/a
|
| SIC | 3634: Electric Housewares and Fans |
| Sales Range | n/a |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 0
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $148,474 | 3,804,514 |
kWh
|
$0.039 |
| Natural Gas | $112,263 | 28,208 |
MMBtu
|
$3.98 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,330 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2514: Cover open tanks | $790 | $200 | - |
$790
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $340 | - |
$340
8,792
kWh
|
- | |
| 03 | 2.3212: Optimize plant power factor | $3,200 | $5,000 |
$3,200
-
kWh
|
- | |
| TOTAL RECOMMENDED | $4,330 | $5,200 |
$3,540
8,792
kWh
|
$790
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs