Assessment Year 1982
Principal Product TIMERS
NAICS
n/a
SIC 3625: Relays and Industrial Controls
Sales Range n/a
# of Employees 200
Plant Area
n/a
Annual Production 1,000,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $121,535 3,072,099
kWh
Natural Gas $13,925 3,302
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $7,433 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $2,431 $1,971 $2,431
61,547
kWh
-
02 2.2514: Cover open tanks $2,342 $400 $2,342
59,203
kWh
-
03 2.2437: Recover waste heat from equipment $2,660 $4,250 - $2,660
-
MMBtu
TOTAL RECOMMENDED $7,433 $6,621 $4,773
120,750
kWh
$2,660
-
MMBtu
TOTAL IMPLEMENTED - - - -