Assessment Year | 1982 |
---|---|
Principal Product | TIMERS |
NAICS |
n/a
|
SIC | 3625: Relays and Industrial Controls |
Sales Range | n/a |
# of Employees | 200 |
Plant Area |
n/a
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $121,535 | 3,072,099 |
kWh
|
$0.040 |
Natural Gas | $13,925 | 3,302 |
MMBtu
|
$4.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,433 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,431 | $1,971 |
$2,431
61,547
kWh
|
- | |
02 | 2.2514: Cover open tanks | $2,342 | $400 |
$2,342
59,203
kWh
|
- | |
03 | 2.2437: Recover waste heat from equipment | $2,660 | $4,250 | - |
$2,660
-
MMBtu
|
|
TOTAL RECOMMENDED | $7,433 | $6,621 |
$4,773
120,750
kWh
|
$2,660
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs