Assessment Year | 1982 |
---|---|
Principal Product | WOMEN'S GARMENTS |
NAICS |
n/a
|
SIC | 2339: Women's, Misses', and Juniors' Outerwear, Not Elsewhere Classified |
Sales Range | $500 k to 1M |
# of Employees | 45 |
Plant Area |
n/a
|
Annual Production | 75,000
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $7,617 | 153,869 |
kWh
|
$0.050 |
Natural Gas | $749 | 186 |
MMBtu
|
$4.03 |
Coal | $2,193 | 1,140 |
MMBtu
|
$1.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,433 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Coal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7291: Reschedule and rearrange multiple-source heating systems | $903 | - | - |
$(-1,290.0)
-
MMBtu
|
$2,193
-
MMBtu
|
|
02 | 2.7111: Reduce illumination to minimum necessary levels | $290 | - |
$290
5,862
kWh
|
- | - | |
03 | 2.7314: Reduce ventilation air | $240 | $150 | - |
$240
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $1,433 | $150 |
$290
5,862
kWh
|
$(-1,050.0)
-
MMBtu
|
$2,193
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs