Assessment Year | 2005 |
---|---|
Principal Product | Injection molded plastics |
NAICS | 333511: Industrial Mold Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 90 |
Plant Area |
63,000
ft2
|
Annual Production | 3,000,000
lb
|
Production Hrs. Annual | 6,408
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $356,037 | 4,785,200 |
kWh
|
$0.074 |
Electricity Demand | $87,111 | 11,960 |
kW-mo/yr
|
$7.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,168 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $12,460 | $8,170 |
$12,460
165,050
kWh
|
- | |
02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $1,365 | $2,620 |
$1,365
18,067
kWh
|
- | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $14,113 | - |
$14,113
186,925
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,990 | - |
$3,390
44,856
kWh
|
$600
-
kW-mo/yr
|
|
05 | 2.4235: Remove or close off unneeded compressed air lines | $700 | $1,070 |
$700
9,320
kWh
|
- | |
TOTAL RECOMMENDED | $32,628 | $11,860 |
$32,028
424,218
kWh
|
$600
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $20,168 | $3,690 |
$19,568
259,168
kWh
|
$600
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs