Assessment Year 2005
Principal Product Wooden Support systems
NAICS 321214: Truss Manufacturing
SIC 2439: Structural Wood Members, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 170
Plant Area 40,000
ft2
Annual Production 15,000,000
thousand feet
Production Hrs. Annual 6,120
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $48,953 761,760
kWh
Electricity Demand $12,227 2,111
kW-mo/yr
Natural Gas $6,683 823
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,690 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,980

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $3,725 - $3,210
51,072
kWh
$515
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,320 $460 $2,860
45,560
kWh
$460
-
kW-mo/yr
-
03 3.5248: Separate and recycle scrap metal to foundry or for sale $1,600 - - - $1,600
-
lb
04 2.4239: Eliminate or reduce compressed air usage $473 - $211
3,360
kWh
$262
-
kW-mo/yr
-
05 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,385 - $1,385
22,060
kWh
- -
06 2.7124: Make a practice of turning off lights when not needed $187 - $150
2,190
kWh
$37
-
kW-mo/yr
-
TOTAL RECOMMENDED $10,690 $460 $7,816
124,242
kWh
$1,274
-
kW-mo/yr
$1,600
-
lb
TOTAL IMPLEMENTED $3,980 $460 $3,221
51,110
kWh
$759
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs