Assessment Year | 2005 |
---|---|
Principal Product | Folding Paperboard |
NAICS | 322212: Folding Paperboard Box Manufacturing |
SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
120,000
ft2
|
Annual Production | 250,000
ton
|
Production Hrs. Annual | 6,184
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $133,907 | 2,162,407 |
kWh
|
$0.062 |
Electricity Demand | $23,487 | 6,918 |
kW-mo/yr
|
$3.40 |
Natural Gas | $11,529 | 1,408 |
MMBtu
|
$8.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,545 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,040 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.7496: Install partitions to reduce size of conditioned space | $13,200 | $25,840 |
$13,200
285,500
kWh
|
- | - | |
02 | 4.652: Replace existing equipment with more suitable substitutes | $12,700 | $5,330 | - | - | $12,700 | |
03 | 2.2437: Recover waste heat from equipment | $11,500 | $2,340 |
$11,500
248,030
kWh
|
- | - | |
04 | 2.4323: Use optimum size and capacity equipment | $8,870 | $13,400 |
$6,970
150,732
kWh
|
$1,900
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,525 | $7,400 |
$5,525
119,500
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,040 | $500 |
$1,700
36,840
kWh
|
$340
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $890 | - |
$727
14,248
kWh
|
$163
-
kW-mo/yr
|
- | |
08 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $645 | - |
$485
10,495
kWh
|
$160
-
kW-mo/yr
|
- | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $175 | - |
$145
3,125
kWh
|
$30
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $55,545 | $54,810 |
$40,252
868,470
kWh
|
$2,593
-
kW-mo/yr
|
$12,700 | ||
TOTAL IMPLEMENTED | $2,040 | $500 |
$1,700
36,840
kWh
|
$340
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs