Assessment Year | 2004 |
---|---|
Principal Product | PEY plastic bottles |
NAICS | 326160: Plastics Bottle Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
225,000
ft2
|
Annual Production | 720,000,000
pieces
|
Production Hrs. Annual | 8,700
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,341,735 | 23,113,426 |
kWh
|
$0.058 |
Electricity Demand | $178,483 | 38,136 |
kW-mo/yr
|
$4.68 |
Electricity Fees | $2,308 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,202,663 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,147,633 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 3.1191: Change procedures / equipment / operating conditions | $1,138,683 | - | - | - |
$1,138,683
-
Tgal
|
|
02 | 2.4323: Use optimum size and capacity equipment | $37,330 | $30,000 |
$32,960
574,200
kWh
|
$4,370
-
kW-mo/yr
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,700 | $36,000 |
$15,650
272,650
kWh
|
$2,050
-
kW-mo/yr
|
- | |
04 | 2.6218: Turn off equipment when not in use | $6,840 | - |
$6,840
119,160
kWh
|
- | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $2,110 | - |
$2,110
36,775
kWh
|
- | - | |
TOTAL RECOMMENDED | $1,202,663 | $66,000 |
$57,560
1,002,785
kWh
|
$6,420
-
kW-mo/yr
|
$1,138,683
-
Tgal
|
||
TOTAL IMPLEMENTED | $1,147,633 | - |
$8,950
155,935
kWh
|
- |
$1,138,683
-
Tgal
|