ITAC Assessment: TA0082
ITAC logo
ITAC Assessment: TA0082
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Bakery Equipment
NAICS 333241: Food Product Machinery Manufacturing
SIC 3556: Food Products Machinery
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 97,000
ft2
Annual Production 4
pieces
Production Hrs. Annual 2,580
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $121,476 1,980,450
kWh
Electricity Demand $45,093 5,916
kW-mo/yr
Electricity Fees $2,219 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $24,175 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,295

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.8114: Change rate schedules or other changes in utility service $14,730 - $14,730
-
kWh
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,395 $960 $1,115
23,660
kWh
$1,280
-
kW-mo/yr
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,170 $10 $1,170
24,885
kWh
-
04 2.7229: Air condition only space necessary $1,090 - $600
12,660
kWh
$490
-
kW-mo/yr
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,970 - $920
19,453
kWh
$1,050
-
kW-mo/yr
06 2.7423: Reduce heat gain by window tinting $2,820 $7,720 $2,820
59,765
kWh
-
TOTAL RECOMMENDED $24,175 $8,690 $21,355
140,423
kWh
$2,820
-
kW-mo/yr
TOTAL IMPLEMENTED $18,295 $970 $17,015
48,545
kWh
$1,280
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs