| Assessment Year | 2004 |
|---|---|
| Principal Product | Institutional Furniture Manufacturing |
| NAICS | 337127: Institutional Furniture Manufacturing |
| SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
| Sales Range | $10 M to 50M |
| # of Employees | 225 |
| Plant Area |
486,000
ft2
|
| Annual Production | 500
pieces
|
| Production Hrs. Annual | 4,328
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $129,497 | 2,398,960 |
kWh
|
$0.054 |
| Electricity Demand | $30,007 | 6,885 |
kW-mo/yr
|
$4.36 |
| Electricity Fees | $456 | - |
|
- |
| Natural Gas | $25,106 | 3,945 |
MMBtu
|
$6.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $49,720 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,945 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $25,095 | $4,666 |
$8,685
143,930
kWh
|
$1,710
-
kW-mo/yr
|
$14,700
-
MMBtu
|
- | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $13,600 | - | - | - | - | $13,600 | |
| 03 | 2.7229: Air condition only space necessary | $7,680 | $150 | - | - |
$7,680
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,360 | $190 |
$2,020
33,500
kWh
|
$340
-
kW-mo/yr
|
- | - | |
| 05 | 2.4238: Do not use compressed air for personal cooling | $775 | - |
$390
6,514
kWh
|
$385
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $210 | $320 |
$192
3,189
kWh
|
$18
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $49,720 | $5,326 |
$11,287
187,133
kWh
|
$2,453
-
kW-mo/yr
|
$22,380
-
MMBtu
|
$13,600 | ||
| TOTAL IMPLEMENTED | $16,945 | $510 |
$2,602
43,203
kWh
|
$743
-
kW-mo/yr
|
- | $13,600 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs