Assessment Year 2003
Principal Product Refigerated dough cans & solid shortening
NAICS 322219: Other Paperboard Container Manufacturing
SIC 2655: Fiber Cans, Tubes, Drums, and Similar Products
Sales Range $10
M
to 50
M
# of Employees 53
Plant Area 1,115,000
ft2
Annual Production 230,000,000
pieces
Production Hrs. Annual 4,800
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $125,500 2,846,280
kWh
Electricity Demand $46,825 7,392
kW-mo/yr
Electricity Fees $6,003 -
Natural Gas $14,904 2,153
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,059 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,961

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7496: Install partitions to reduce size of conditioned space $9,350 $1,800 $9,350
221,160
kWh
- -
02 2.7124: Make a practice of turning off lights when not needed $7,450 - $5,900
140,025
kWh
$1,550
-
kW-mo/yr
-
03 2.8121: Apply for tax-free status for energy purchases $4,613 - - - $4,613
04 2.6218: Turn off equipment when not in use $1,770 - $1,400
33,480
kWh
$370
-
kW-mo/yr
-
05 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $1,740 $520 $1,740
40,845
kWh
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $1,035 - $830
19,584
kWh
$205
-
kW-mo/yr
-
07 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $101 $211 $101
2,410
kWh
- -
TOTAL RECOMMENDED $26,059 $2,531 $19,321
457,504
kWh
$2,125
-
kW-mo/yr
$4,613
TOTAL IMPLEMENTED $12,961 $2,531 $12,591
297,895
kWh
$370
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs