Assessment Year | 2003 |
---|---|
Principal Product | Snack Foods |
NAICS | 311423: Dried and Dehydrated Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 100 |
Plant Area |
65,000
ft2
|
Annual Production | 26,000,000
lb
|
Production Hrs. Annual | 6,336
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $128,995 | 2,924,994 |
kWh
|
$0.044 |
Electricity Demand | $31,482 | 7,875 |
kW-mo/yr
|
$4.00 |
Electricity Fees | $3,819 | - |
|
- |
Natural Gas | $709,917 | 198,204 |
MMBtu
|
$3.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $512,771 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $63,789 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4325: Upgrade conveyors | $430,950 | $202,900 | - | - | - | - | $430,950 | |
02 | 2.2443: Re-use or recycle hot or cold process exhaust air | $47,100 | $5,202 | - | - |
$47,100
-
MMBtu
|
- | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,258 | $8,100 |
$6,258
141,926
kWh
|
- | - | - | - | |
04 | 4.131: Modify process to reduce material use/cost | $13,150 | - | - | - | - | - | $13,150 | |
05 | 2.4321: Upgrade obsolete equipment | $5,795 | $11,200 |
$5,795
131,407
kWh
|
- | - | - | - | |
06 | 3.1191: Change procedures / equipment / operating conditions | $4,492 | - | - | - | - |
$4,492
-
Tgal
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,570 | - |
$2,190
49,724
kWh
|
$380
-
kW-mo/yr
|
- | - | - | |
08 | 2.6218: Turn off equipment when not in use | $1,676 | - |
$1,676
38,000
kWh
|
- | - | - | - | |
09 | 2.7111: Reduce illumination to minimum necessary levels | $390 | - |
$390
8,921
kWh
|
- | - | - | - | |
10 | 2.7111: Reduce illumination to minimum necessary levels | $390 | - |
$390
8,921
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $512,771 | $227,402 |
$16,699
378,899
kWh
|
$380
-
kW-mo/yr
|
$47,100
-
MMBtu
|
$4,492
-
Tgal
|
$444,100 | ||
TOTAL IMPLEMENTED | $63,789 | $24,502 |
$16,309
369,978
kWh
|
$380
-
kW-mo/yr
|
$47,100
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs