Assessment Year 2002
Principal Product Wire and Metal Display Products
NAICS
n/a
SIC 3496: Miscellaneous Fabricated Wire Products
Sales Range $5
M
to 10
M
# of Employees 100
Plant Area 100,000
ft2
Annual Production 300,000
pieces
Production Hrs. Annual 2,570
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $61,075 1,020,567
kWh
Electricity Demand $16,358 5,486
kW-mo/yr
Electricity Fees $19,522 -
Natural Gas $31,551 2,984
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,243 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $31,623

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings
01 3.5315: Lease / purchase baler; sell cardboard to recycler $19,125 $7,500 - - - - $19,125
-
Tgal
02 2.8114: Change rate schedules or other changes in utility service $6,660 - - - $6,660 - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,280 $135 $2,630
40,970
kWh
$650
-
kW-mo/yr
- - -
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,244 $5 $2,244
34,938
kWh
- - - -
05 2.7111: Reduce illumination to minimum necessary levels $980 $30 $790
12,336
kWh
$190
-
kW-mo/yr
- - -
06 2.7124: Make a practice of turning off lights when not needed $640 - $640
9,970
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $204 $296 $190
2,940
kWh
$14
-
kW-mo/yr
- - -
08 2.2511: Insulate bare equipment $110 $100 - - - $110
-
MMBtu
-
TOTAL RECOMMENDED $33,243 $8,066 $6,494
101,154
kWh
$854
-
kW-mo/yr
$6,660 $110
-
MMBtu
$19,125
-
Tgal
TOTAL IMPLEMENTED $31,623 $8,036 $5,064
78,848
kWh
$664
-
kW-mo/yr
$6,660 $110
-
MMBtu
$19,125
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs