ITAC Assessment: TA0032
ITAC logo
ITAC Assessment: TA0032
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product Automotive Sub-Assembly
NAICS
n/a
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 539
Plant Area 500,000
ft2
Annual Production 0
units
Production Hrs. Annual 6,072
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $323,713 7,422,300
kWh
Electricity Demand $116,827 14,316
kW-mo/yr
Electricity Fees $81,633 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $113,965 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $113,065

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings
01 3.5316: Contract a wood pallet recycling company $39,000 - - - - $39,000
-
Tgal
02 2.8121: Apply for tax-free status for energy purchases $37,007 - - - $37,007 -
03 2.7111: Reduce illumination to minimum necessary levels $28,990 $900 $17,590
466,329
kWh
$11,400
-
kW-mo/yr
- -
04 2.8123: Pay utility bills on time $7,678 - - - $7,678 -
05 2.7111: Reduce illumination to minimum necessary levels $900 $55 $550
14,570
kWh
$350
-
kW-mo/yr
- -
06 2.7135: Install occupancy sensors $390 $256 $390
10,300
kWh
- - -
TOTAL RECOMMENDED $113,965 $1,211 $18,530
491,199
kWh
$11,750
-
kW-mo/yr
$44,685 $39,000
-
Tgal
TOTAL IMPLEMENTED $113,065 $1,156 $17,980
476,629
kWh
$11,400
-
kW-mo/yr
$44,685 $39,000
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs