Assessment Year | 2002 |
---|---|
Principal Product | Corrugated Boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
239,000
ft2
|
Annual Production | 4,000,000,000
thousand feet
|
Production Hrs. Annual | 6,264
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $157,712 | 4,401,256 |
kWh
|
$0.036 |
Electricity Demand | $68,448 | 8,388 |
kW-mo/yr
|
$8.16 |
Electricity Fees | $24,252 | - |
|
- |
Natural Gas | $230,836 | 50,994 |
MMBtu
|
$4.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $37,915 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,415 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7229: Air condition only space necessary | $16,500 | $31,000 | - | - |
$16,500
-
MMBtu
|
|
02 | 2.2135: Repair and eliminate steam leaks | $11,090 | $480 | - | - |
$11,090
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,000 | $840 |
$5,000
162,634
kWh
|
- | - | |
04 | 2.2136: Install / repair insulation on steam lines | $4,520 | $1,200 | - | - |
$4,520
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $390 | $180 |
$390
12,650
kWh
|
- | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $315 | - |
$180
5,763
kWh
|
$135
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $100 | $200 |
$60
1,962
kWh
|
$40
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $37,915 | $33,900 |
$5,630
183,009
kWh
|
$175
-
kW-mo/yr
|
$32,110
-
MMBtu
|
||
TOTAL IMPLEMENTED | $21,415 | $2,900 |
$5,630
183,009
kWh
|
$175
-
kW-mo/yr
|
$15,610
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs