Assessment Year 2011
Principal Product Poly Bags
NAICS 326111: Plastics Bag and Pouch Manufacturing
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 146,000
ft2
Annual Production 12,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $197,015 3,068,000
kWh
Electricity Demand $69,440 6,944
kW-mo/yr
Electricity Fees $5,329 -
Natural Gas $1,135 108
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,210 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $24,333

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings
01 2.7224: Reduce space conditioning during non-working hours $18,083 $810 $17,728
276,058
kWh
- $355 -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,629 $61,377 $4,326
67,356
kWh
$217
-
kW-mo/yr
$87 -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,621 $360 $1,269
19,757
kWh
$320
-
kW-mo/yr
$32 -
04 2.7111: Reduce illumination to minimum necessary levels $1,287 $395 $887
13,810
kWh
$375
-
kW-mo/yr
$25 -
05 2.7135: Install occupancy sensors $432 $900 $423
6,590
kWh
- $8 -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $396 $280 $149
2,324
kWh
$32
-
kW-mo/yr
$4 $211
07 2.7142: Utilize higher efficiency lamps and/or ballasts $308 $1,155 $182
2,831
kWh
$120
-
kW-mo/yr
$6 -
08 2.6211: Conserve energy by efficient use of vending machines $278 $368 $224
3,494
kWh
$48
-
kW-mo/yr
$5 -
09 2.7134: Use photocell controls $177 $30 $173
2,700
kWh
- $3 -
TOTAL RECOMMENDED $27,210 $65,674 $25,362
394,920
kWh
$1,113
-
kW-mo/yr
$525 $211
TOTAL IMPLEMENTED $24,333 $62,547 $23,323
363,171
kWh
$537
-
kW-mo/yr
$473 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs