Assessment Year 2002
Principal Product Bulk Material;Conveyor
NAICS
n/a
SIC 3535: Conveyors and Conveying Equipment
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 64,000
ft2
Annual Production 3,854
pieces
Production Hrs. Annual 3,383
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $110,413 1,469,776
kWh
Electricity Demand $15,042 2,212
kW-mo/yr
Electricity Fees $600 -
Natural Gas $31,984 27,035
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,885 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,180

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 4.452: Eliminate shift $6,585 - $6,585
67,510
kWh
-
02 4.132: Purchase new equipment to reduce material use / cost $6,400 $8,400 - $6,400
03 2.6218: Turn off equipment when not in use $1,370 $40 $1,370
39,270
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $940 $150 $940
27,000
kWh
-
05 2.4314: Use synthetic lubricant $470 - $470
6,400
kWh
-
06 2.7135: Install occupancy sensors $120 $130 $120
3,370
kWh
-
TOTAL RECOMMENDED $15,885 $8,720 $9,485
143,550
kWh
$6,400
TOTAL IMPLEMENTED $9,180 $8,590 $2,780
72,670
kWh
$6,400
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings