Assessment Year | 2002 |
---|---|
Principal Product | Bulk Material;Conveyor |
NAICS |
n/a
|
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
64,000
ft2
|
Annual Production | 3,854
pieces
|
Production Hrs. Annual | 3,383
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $110,413 | 1,469,776 |
kWh
|
$0.075 |
Electricity Demand | $15,042 | 2,212 |
kW-mo/yr
|
$6.80 |
Electricity Fees | $600 | - |
|
- |
Natural Gas | $31,984 | 27,035 |
MMBtu
|
$1.18 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,885 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,180 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 4.452: Eliminate shift | $6,585 | - |
$6,585
67,510
kWh
|
- | |
02 | 4.132: Purchase new equipment to reduce material use / cost | $6,400 | $8,400 | - | $6,400 | |
03 | 2.6218: Turn off equipment when not in use | $1,370 | $40 |
$1,370
39,270
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $940 | $150 |
$940
27,000
kWh
|
- | |
05 | 2.4314: Use synthetic lubricant | $470 | - |
$470
6,400
kWh
|
- | |
06 | 2.7135: Install occupancy sensors | $120 | $130 |
$120
3,370
kWh
|
- | |
TOTAL RECOMMENDED | $15,885 | $8,720 |
$9,485
143,550
kWh
|
$6,400 | ||
TOTAL IMPLEMENTED | $9,180 | $8,590 |
$2,780
72,670
kWh
|
$6,400 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs