Assessment Year | 2002 |
---|---|
Principal Product | Envelopes |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
200,000
ft2
|
Annual Production | 1,500,000,000
pieces
|
Production Hrs. Annual | 6,408
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $139,073 | 3,172,925 |
kWh
|
$0.044 |
Electricity Demand | $58,185 | 7,145 |
kW-mo/yr
|
$8.14 |
Electricity Fees | $32,058 | - |
|
- |
Natural Gas | $10,813 | 1,132 |
MMBtu
|
$9.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,751 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,406 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $16,833 | - | - | - | $16,833 | |
02 | 2.8123: Pay utility bills on time | $1,006 | - | - | - | $1,006 | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $790 | $160 |
$480
13,534
kWh
|
$310
-
kW-mo/yr
|
- | |
04 | 2.4235: Remove or close off unneeded compressed air lines | $660 | - |
$660
18,405
kWh
|
- | - | |
05 | 2.7494: Install storm windows and doors | $345 | $481 |
$345
9,554
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $117 | $220 |
$80
2,207
kWh
|
$37
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $19,751 | $861 |
$1,565
43,700
kWh
|
$347
-
kW-mo/yr
|
$17,839 | ||
TOTAL IMPLEMENTED | $19,406 | $380 |
$1,220
34,146
kWh
|
$347
-
kW-mo/yr
|
$17,839 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs