| Assessment Year | 2001 |
|---|---|
| Principal Product | Construction Machinery |
| NAICS |
n/a
|
| SIC | 3531: Construction Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
537,000
ft2
|
| Annual Production | 40
units
|
| Production Hrs. Annual | 2,148
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $35,047 | 736,320 |
kWh
|
$0.048 |
| Electricity Demand | $23,785 | 2,993 |
kW-mo/yr
|
$7.95 |
| Electricity Fees | $2,718 | - |
|
- |
| Natural Gas | $7,446 | 904 |
MMBtu
|
$8.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,694 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,564 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $6,600 | $192 |
$6,600
182,995
kWh
|
- | - | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $4,400 | - | - |
$4,400
-
kW-mo/yr
|
- | |
| 03 | 4.821: Pay bills on time to avoid late fees | $269 | - | - | - | $269 | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $295 | $6 |
$295
8,186
kWh
|
- | - | |
| 05 | 2.4314: Use synthetic lubricant | $130 | - |
$43
1,205
kWh
|
$87
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $11,694 | $198 |
$6,938
192,386
kWh
|
$4,487
-
kW-mo/yr
|
$269 | ||
| TOTAL IMPLEMENTED | $11,564 | $198 |
$6,895
191,181
kWh
|
$4,400
-
kW-mo/yr
|
$269 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs