| Assessment Year | 2001 |
|---|---|
| Principal Product | PVC Core Foam |
| NAICS |
n/a
|
| SIC | 3086: Plastics Foam Products |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
80,000
ft2
|
| Annual Production | 1,670
ton
|
| Production Hrs. Annual | 8,328
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $197,907 | 5,733,540 |
kWh
|
$0.035 |
| Electricity Demand | $86,959 | 10,624 |
kW-mo/yr
|
$8.19 |
| Electricity Fees | $2,578 | - |
|
- |
| Natural Gas | $48,213 | 50,944 |
MMBtu
|
$0.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,447 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,985 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2136: Install / repair insulation on steam lines | $8,063 | $1,741 | - | - |
$8,063
-
MMBtu
|
|
| 02 | 2.2511: Insulate bare equipment | $5,666 | $2,886 | - | - |
$5,666
-
MMBtu
|
|
| 03 | 2.6218: Turn off equipment when not in use | $3,918 | - |
$3,918
117,261
kWh
|
- | - | |
| 04 | 2.4314: Use synthetic lubricant | $2,175 | - |
$1,269
37,987
kWh
|
$906
-
kW-mo/yr
|
- | |
| 05 | 2.6215: Shut off air conditioning in winter heating season | $2,036 | - | - | - |
$2,036
-
MMBtu
|
|
| 06 | 2.7132: Install timers on light switches in little used areas | $999 | $46 |
$495
14,840
kWh
|
$504
-
kW-mo/yr
|
- | |
| 07 | 2.7135: Install occupancy sensors | $303 | $313 |
$303
9,069
kWh
|
- | - | |
| 08 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $287 | $23 | - | - |
$287
-
MMBtu
|
|
| TOTAL RECOMMENDED | $23,447 | $5,009 |
$5,985
179,157
kWh
|
$1,410
-
kW-mo/yr
|
$16,052
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $20,985 | $4,986 |
$4,716
141,170
kWh
|
$504
-
kW-mo/yr
|
$15,765
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs