Assessment Year 2001
Principal Product PVC Core Foam
NAICS
n/a
SIC 3086: Plastics Foam Products
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 80,000
ft2
Annual Production 1,670
ton
Production Hrs. Annual 8,328
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $197,907 5,733,540
kWh
Electricity Demand $86,959 10,624
kW-mo/yr
Electricity Fees $2,578 -
Natural Gas $48,213 50,944
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,447 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,985

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2136: Install / repair insulation on steam lines $8,063 $1,741 - - $8,063
-
MMBtu
02 2.2511: Insulate bare equipment $5,666 $2,886 - - $5,666
-
MMBtu
03 2.6218: Turn off equipment when not in use $3,918 - $3,918
117,261
kWh
- -
04 2.4314: Use synthetic lubricant $2,175 - $1,269
37,987
kWh
$906
-
kW-mo/yr
-
05 2.6215: Shut off air conditioning in winter heating season $2,036 - - - $2,036
-
MMBtu
06 2.7132: Install timers on light switches in little used areas $999 $46 $495
14,840
kWh
$504
-
kW-mo/yr
-
07 2.7135: Install occupancy sensors $303 $313 $303
9,069
kWh
- -
08 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas $287 $23 - - $287
-
MMBtu
TOTAL RECOMMENDED $23,447 $5,009 $5,985
179,157
kWh
$1,410
-
kW-mo/yr
$16,052
-
MMBtu
TOTAL IMPLEMENTED $20,985 $4,986 $4,716
141,170
kWh
$504
-
kW-mo/yr
$15,765
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs