| Assessment Year | 2026 |
|---|---|
| Principal Product | Precision Mold Components |
| NAICS | 333514: Special Die and Tool, Die Set, Jig, and Fixture Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 57 |
| Plant Area |
42,000
ft2
|
| Annual Production | 878,000
units
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $167,957 | 2,582,811 |
kWh
|
$0.065 | |
| Electricity Demand | $85,795 | 5,521 |
kW-mo/yr
|
$15.54 | |
| Electricity Fees | $58,736 | - |
|
- | |
| Natural Gas | $7,933 | 1,059 |
MMBtu
|
$7.49 | |
| Other Gas | $630 | 1 |
MMBtu
|
$630.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $5,280 | 284 |
Tgal
|
$18.59 | |
| TOTAL YEARLY COSTS | $326,331 | ||||
| RECOMMENDED SAVINGS* | $85,290 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $17,922 | - | - | - | - | $17,922 | |
| 02 | 3.1161: Eliminate/reduce an operation | $1,715 | - |
$622
9,563
kWh
|
$1,399
-
kW-mo/yr
|
$(-305.6)
-
MMBtu
|
- | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,515 | - |
$5,515
84,846
kWh
|
- | - | - | |
| 04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,289 | - | - |
$4,289
-
kW-mo/yr
|
- | - | |
| 05 | 2.7144: Install spectral reflectors / delamp | $41,147 | $480 |
$29,748
457,667
kWh
|
$11,398
-
kW-mo/yr
|
- | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $864 | $261 |
$864
13,289
kWh
|
- | - | - | |
| 07 | 2.7135: Install occupancy sensors | $4,982 | $1,557 |
$4,982
76,644
kWh
|
- | - | - | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,742 | $2,467 | - | - |
$1,742
-
MMBtu
|
- | |
| 09 | 2.6211: Conserve energy by efficient use of vending machines | $379 | $741 |
$379
5,825
kWh
|
- | - | - | |
| 10 | 2.4322: Use or replace with energy efficient substitutes | $242 | $749 |
$11
175
kWh
|
$4
-
kW-mo/yr
|
- | $227 | |
| 11 | 2.5117: Convert to indirect temperature control system | $6,495 | $52,500 |
$3,537
54,412
kWh
|
$2,165
-
kW-mo/yr
|
$793
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $85,290 | $58,755 |
$45,657
702,421
kWh
|
$19,255
-
kW-mo/yr
|
$2,230
-
MMBtu
|
$18,148 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs