| Assessment Year | 2025 |
|---|---|
| Principal Product | Plastic Parts |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 205 |
| Plant Area |
125,000
ft2
|
| Annual Production | 776,789,970
pieces
|
| Production Hrs. Annual | 8,712
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $540,010 | 8,624,157 |
kWh
|
$0.063 | |
| Electricity Demand | $317,223 | 29,080 |
kW-mo/yr
|
$10.91 | |
| Electricity Fees | $115,867 | - |
|
- | |
| Natural Gas | $9,554 | 1,055 |
MMBtu
|
$9.06 | |
| Other Gas | $1,139 | 1 |
MMBtu
|
$1,139.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $23,266 | 5,195 |
Tgal
|
$4.48 | |
| TOTAL YEARLY COSTS | $1,007,059 | ||||
| RECOMMENDED SAVINGS* | $69,017 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,769 | $136 |
$13,769
218,553
kWh
|
- | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,902 | $136 |
$1,902
30,187
kWh
|
- | - | - | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $1,333 | $105 |
$907
14,400
kWh
|
$982
-
kW-mo/yr
|
$(-556.4)
-
MMBtu
|
- | |
| 04 | 2.5117: Convert to indirect temperature control system | $49,190 | $284,250 |
$27,001
431,208
kWh
|
$15,861
-
kW-mo/yr
|
$478
-
MMBtu
|
$5,850 | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $292 | $2,044 | - | - |
$292
-
MMBtu
|
- | |
| 06 | 2.7232: Replace existing hvac unit with high efficiency model | $2,533 | $25,972 |
$692
10,980
kWh
|
- |
$1,841
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $69,017 | $312,643 |
$44,270
705,328
kWh
|
$16,843
-
kW-mo/yr
|
$2,054
-
MMBtu
|
$5,850 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs