Assessment Year | 2025 |
---|---|
Principal Product | Bottled Spring Water |
NAICS | 312112: Bottled Water Manufacturing |
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $10 M to 50M |
# of Employees | 52 |
Plant Area |
230,454
ft2
|
Annual Production | 10,000,000
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $213,795 | 3,650,733 |
kWh
|
$0.059 |
Electricity Demand | $328,657 | 32,186 |
kW-mo/yr
|
$10.21 |
Electricity Fees | $61,243 | - |
|
- |
LPG | $84,716 | 3,713 |
MMBtu
|
$22.82 |
TOTAL YEARLY COSTS | $688,412 | |||
RECOMMENDED SAVINGS* | $150,255 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $30,496 | - | - | - | - | $30,496 | |
02 | 2.7224: Reduce space conditioning during non-working hours | $6,574 | $1,490 | - | - |
$6,574
-
MMBtu
|
- | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $3,146 | $1,150 |
$2,543
43,099
kWh
|
$603
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,489 | $3,432 |
$1,197
20,293
kWh
|
$363
-
kW-mo/yr
|
- | $2,929 | |
05 | 2.4322: Use or replace with energy efficient substitutes | $764 | $2,693 |
$393
6,658
kWh
|
$93
-
kW-mo/yr
|
- | $278 | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $683 | $2,500 |
$683
11,572
kWh
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,969 | $16,085 |
$2,103
35,638
kWh
|
$1,866
-
kW-mo/yr
|
- | - | |
08 | 2.9114: Use solar heat to make electricty | $100,134 | $628,503 |
$100,134
1,697,194
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $150,255 | $655,854 |
$107,053
1,814,454
kWh
|
$2,925
-
kW-mo/yr
|
$6,574
-
MMBtu
|
$33,703 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs