Assessment Year | 2025 |
---|---|
Principal Product | Medical and biotech injection molded parts |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 117 |
Plant Area |
105,753
ft2
|
Annual Production | 262,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $308,472 | 14,148,262 |
kWh
|
$0.022 | |
Electricity Demand | $129,228 | 10,559 |
kW-mo/yr
|
$12.24 | |
Electricity Fees | $63,317 | - |
|
- | |
Natural Gas | $7,005 | 1,387 |
MMBtu
|
$5.05 | |
Other Gas | $661 | 1 |
MMBtu
|
$661.16 | |
Waste Disposal Costs | |||||
Water Usage | $4,000 | 960,000 |
Tgal
|
$0.004 | |
TOTAL YEARLY COSTS | $512,683 | ||||
RECOMMENDED SAVINGS* | $52,947 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $22,712 | $50 | - | - | $22,183 | - | $529 | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,415 | - | - |
$6,415
-
kW-mo/yr
|
- | - | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $662 | - |
$662
30,117
kWh
|
- | - | - | - | |
04 | 2.7122: Disconnect ballasts | $543 | - |
$308
14,016
kWh
|
$235
-
kW-mo/yr
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $665 | $428 |
$665
30,214
kWh
|
- | - | - | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $647 | $63 |
$210
9,563
kWh
|
$643
-
kW-mo/yr
|
- |
$(-206.3)
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,960 | $8,397 |
$2,960
134,554
kWh
|
$2,256
-
kW-mo/yr
|
- | - | $1,744 | |
08 | 2.4322: Use or replace with energy efficient substitutes | $965 | $1,882 |
$199
9,023
kWh
|
$152
-
kW-mo/yr
|
- | - | $615 | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $702 | $1,754 |
$339
15,411
kWh
|
$363
-
kW-mo/yr
|
- | - | - | |
10 | 2.6211: Conserve energy by efficient use of vending machines | $67 | $383 |
$67
3,066
kWh
|
- | - | - | - | |
11 | 2.9114: Use solar heat to make electricty | $12,609 | $285,164 |
$12,609
573,156
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $52,947 | $298,120 |
$18,019
819,120
kWh
|
$10,063
-
kW-mo/yr
|
$22,183 |
$(-206.3)
-
MMBtu
|
$2,888 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs