Assessment Year 2024
Principal Product Defense/civil aviation sensor systems
NAICS 334290: Other Communications Equipment Manufacturing
SIC 3812: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical Systems and Instruments
Sales Range $1
M
to 5
M
# of Employees 510
Plant Area 90,000
ft2
Annual Production 1,000
units
Production Hrs. Annual 2,600
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $123,807 2,534,857
kWh
Electricity Demand $64,984 5,173
kW-mo/yr
Electricity Fees $23,786 -
Natural Gas $22,977 3,930
MMBtu
Other Gas $2,209 3,930
MMBtu
TOTAL YEARLY COSTS $237,764
RECOMMENDED SAVINGS* $4,042 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7122: Disconnect ballasts $423 - $194
3,952
kWh
$229
-
kW-mo/yr
- -
02 2.7135: Install occupancy sensors $367 - $367
7,488
kWh
- - -
03 4.821: Pay bills on time to avoid late fees $147 - - - - $147
04 2.4322: Use or replace with energy efficient substitutes $1,444 $138 $551
11,250
kWh
$612
-
kW-mo/yr
$281
-
MMBtu
-
05 2.6218: Turn off equipment when not in use $1,334 $220 $987
20,148
kWh
$347
-
kW-mo/yr
- -
06 2.6211: Conserve energy by efficient use of vending machines $327 $620 $327
7,326
kWh
- - -
TOTAL RECOMMENDED $4,042 $978 $2,426
50,164
kWh
$1,188
-
kW-mo/yr
$281
-
MMBtu
$147
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs