Assessment Year | 2022 |
---|---|
Principal Product | Storage and Distribution of food and paper |
NAICS | 493110: General Warehousing and Storage |
SIC | 4225: General Warehousing and Storage |
Sales Range | $100 M to 500M |
# of Employees | 90 |
Plant Area |
56,000
ft2
|
Annual Production | 6,100,000
units
|
Production Hrs. Annual | 8,281
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $78,294 | 1,559,082 |
kWh
|
$0.050 |
Electricity Demand | $57,966 | 3,391 |
kW-mo/yr
|
$17.09 |
Electricity Fees | $29,398 | - |
|
- |
Natural Gas | $9,828 | 1,603 |
MMBtu
|
$6.13 |
TOTAL YEARLY COSTS | $175,486 | |||
RECOMMENDED SAVINGS* | $30,203 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7122: Disconnect ballasts | $4,994 | - |
$3,089
61,781
kWh
|
$1,905
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,899 | $250 |
$5,908
118,154
kWh
|
$3,980
-
kW-mo/yr
|
- | $12 | |
03 | 2.4322: Use or replace with energy efficient substitutes | $659 | $19 |
$252
5,040
kWh
|
$538
-
kW-mo/yr
|
$(-131.8)
-
MMBtu
|
- | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,907 | $675 | - |
$2,907
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $652 | $567 |
$652
13,032
kWh
|
- | - | - | |
06 | 2.2511: Insulate bare equipment | $1,859 | $2,600 |
$(-216.7)
(-4,335)
kWh
|
$(-176.0)
-
kW-mo/yr
|
$2,251
-
MMBtu
|
- | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $125 | $325 |
$125
2,500
kWh
|
- | - | - | |
08 | 2.7314: Reduce ventilation air | $346 | $1,265 |
$49
994
kWh
|
- |
$297
-
MMBtu
|
- | |
09 | 2.9114: Use solar heat to make electricty | $8,763 | $47,904 |
$8,763
175,250
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $30,203 | $53,604 |
$18,621
372,416
kWh
|
$9,154
-
kW-mo/yr
|
$2,417
-
MMBtu
|
$12 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |