Assessment Year 2022
Principal Product Storage and Distribution of food and paper
NAICS 493110: General Warehousing and Storage
SIC 4225: General Warehousing and Storage
Sales Range $100
M
to 500
M
# of Employees 90
Plant Area 56,000
ft2
Annual Production 6,100,000
units
Production Hrs. Annual 8,281
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $78,294 1,559,082
kWh
Electricity Demand $57,966 3,391
kW-mo/yr
Electricity Fees $29,398 -
Natural Gas $9,828 1,603
MMBtu
TOTAL YEARLY COSTS $175,486
RECOMMENDED SAVINGS* $30,203 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7122: Disconnect ballasts $4,994 - $3,089
61,781
kWh
$1,905
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $9,899 $250 $5,908
118,154
kWh
$3,980
-
kW-mo/yr
- $12
03 2.4322: Use or replace with energy efficient substitutes $659 $19 $252
5,040
kWh
$538
-
kW-mo/yr
$(-131.8)
-
MMBtu
-
04 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,907 $675 - $2,907
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $652 $567 $652
13,032
kWh
- - -
06 2.2511: Insulate bare equipment $1,859 $2,600 $(-216.7)
(-4,335)
kWh
$(-176.0)
-
kW-mo/yr
$2,251
-
MMBtu
-
07 2.6211: Conserve energy by efficient use of vending machines $125 $325 $125
2,500
kWh
- - -
08 2.7314: Reduce ventilation air $346 $1,265 $49
994
kWh
- $297
-
MMBtu
-
09 2.9114: Use solar heat to make electricty $8,763 $47,904 $8,763
175,250
kWh
- - -
TOTAL RECOMMENDED $30,203 $53,604 $18,621
372,416
kWh
$9,154
-
kW-mo/yr
$2,417
-
MMBtu
$12
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs