Assessment Year 2021
Principal Product Automotive Heat exchangers
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 120
Plant Area 272,000
ft2
Annual Production 15,000
units
Production Hrs. Annual 2,610
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $40,657 2,699,042
kWh
Electricity Demand $193,798 26,257
kW-mo/yr
Electricity Fees $48,368 -
Natural Gas $116,630 42,627
MMBtu
Other Energy $3,902 4,558,597
MMBtu
TOTAL YEARLY COSTS $403,355
RECOMMENDED SAVINGS* $58,035 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,108

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 4.821: Pay bills on time to avoid late fees $1,720 - - - - - $1,720
02 2.8121: Apply for tax-free status for energy purchases $23,973 $120 - - - - $23,973
03 2.8121: Apply for tax-free status for energy purchases $7,147 $120 - - - - $7,147
04 2.7314: Reduce ventilation air $4,625 $882 $709
47,251
kWh
- $3,916
-
MMBtu
- -
05 2.2136: Install / repair insulation on steam lines $191 $203 - - $191
-
MMBtu
- -
06 3.1161: Eliminate/reduce an operation $2,822 $3,300 $(-16.5)
(-1,100)
kWh
$(-749.2)
-
kW-mo/yr
- - $3,588
07 2.7142: Utilize higher efficiency lamps and/or ballasts $6,661 $7,939 $1,621
108,068
kWh
$4,785
-
kW-mo/yr
- - $255
08 2.7241: Install outside air damper / economizer on hvac unit $10,521 $22,840 - - $10,521
-
MMBtu
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $375 $1,259 $63
4,205
kWh
$43
-
kW-mo/yr
- $174 $95
TOTAL RECOMMENDED $58,035 $36,663 $2,377
158,424
kWh
$4,079
-
kW-mo/yr
$14,628
-
MMBtu
$174 $36,778
TOTAL IMPLEMENTED $5,108 $4,762 $47
3,105
kWh
$(-706.7)
-
kW-mo/yr
$191
-
MMBtu
$174 $5,403
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings