Assessment Year | 2021 |
---|---|
Principal Product | Power transmission shafts |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 220 |
Plant Area |
133,000
ft2
|
Annual Production | 1,000
units
|
Production Hrs. Annual | 2,610
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $596,392 | 6,552,347 |
kWh
|
$0.091 | |
Electricity Fees | $1,508 | - |
|
- | |
Natural Gas | $29,783 | 6,097 |
MMBtu
|
$4.88 | |
Waste Disposal Costs | |||||
Water Usage | $12,500 | 430,000 |
Tgal
|
$0.029 | |
TOTAL YEARLY COSTS | $640,183 | ||||
RECOMMENDED SAVINGS* | $8,885 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $7,156 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,730 | - |
$1,730
19,218
kWh
|
- | |
02 | 2.8121: Apply for tax-free status for energy purchases | $673 | $100 | - | $673 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,987 | $2,215 |
$4,448
48,867
kWh
|
$1,539 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $496 | $365 |
$474
5,265
kWh
|
$22 | |
TOTAL RECOMMENDED | $8,885 | $2,680 |
$6,651
73,350
kWh
|
$2,234 | ||
TOTAL IMPLEMENTED | $7,156 | $2,680 |
$4,922
54,132
kWh
|
$2,234 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs