| Assessment Year | 2019 |
|---|---|
| Principal Product | Radiators |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
353,403
ft2
|
| Annual Production | 17,336,652
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $462,988 | 8,659,916 |
kWh
|
$0.053 | |
| Electricity Demand | $100,711 | 28,587 |
kW-mo/yr
|
$3.52 | |
| Electricity Fees | $13,209 | - |
|
- | |
| Natural Gas | $198,793 | 50,435 |
MMBtu
|
$3.94 | |
| Waste Disposal Costs | |||||
| Water Usage | $64,400 | 15,470 |
Tgal
|
$4.16 | |
| Other Liquid (non-haz) | $2,800 | 1 |
gal
|
$2,800.00 | |
| Solid Waste (non-haz) | $20,700 | 1 |
lb
|
$20,700.00 | |
| TOTAL YEARLY COSTS | $863,601 | ||||
| RECOMMENDED SAVINGS* | $41,734 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $1,213 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $359 | - | - | - |
$359
-
MMBtu
|
- | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $1,163 | $99 |
$1,102
20,790
kWh
|
$407
-
kW-mo/yr
|
$(-346.0)
-
MMBtu
|
- | - | |
| 03 | 2.7314: Reduce ventilation air | $4,494 | $890 |
$1,431
26,998
kWh
|
- |
$3,063
-
MMBtu
|
- | - | |
| 04 | 3.1161: Eliminate/reduce an operation | $6,082 | $2,288 |
$(-209.5)
(-3,952)
kWh
|
$(-274.8)
-
kW-mo/yr
|
- | - | $6,566 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26,788 | $21,904 |
$19,672
371,178
kWh
|
$3,798
-
kW-mo/yr
|
- | - | $3,318 | |
| 06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $869 | $845 | - | - |
$869
-
MMBtu
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $802 | $857 |
$404
7,621
kWh
|
$37
-
kW-mo/yr
|
- | $191 | $171 | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $411 | $839 |
$411
7,747
kWh
|
- | - | - | - | |
| 09 | 2.7135: Install occupancy sensors | $767 | $2,060 |
$767
14,475
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $41,734 | $29,782 |
$23,577
444,857
kWh
|
$3,967
-
kW-mo/yr
|
$3,945
-
MMBtu
|
$191 | $10,055 | ||
| TOTAL IMPLEMENTED | $1,213 | $1,696 |
$815
15,368
kWh
|
$37
-
kW-mo/yr
|
- | $191 | $171 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs