ITAC Assessment: SU0462
ITAC logo
ITAC Assessment: SU0462
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Custom Fabricated Plastic Parts
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 23
Plant Area 31,000
ft2
Annual Production 394,102
units
Production Hrs. Annual 4,290
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $9,953 144,640
kWh
Electricity Demand $9,513 934
kW-mo/yr
Electricity Fees $4,289 -
LPG $18,373 1,059
MMBtu
Waste Disposal Costs
Water Usage $806 106
Tgal
TOTAL YEARLY COSTS $42,934
RECOMMENDED SAVINGS* $8,485 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings LPG Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7224: Reduce space conditioning during non-working hours $857 - - - - $857
-
MMBtu
- -
02 4.821: Pay bills on time to avoid late fees $417 - - - $417 - - -
03 2.8121: Apply for tax-free status for energy purchases $1,176 $83 - - - - - $1,176
04 2.8121: Apply for tax-free status for energy purchases $501 $83 - - - - - $501
05 2.7142: Utilize higher efficiency lamps and/or ballasts $631 $408 $309
4,472
kWh
$136
-
kW-mo/yr
- - $170 $16
06 2.2136: Install / repair insulation on steam lines $1,092 $764 - - - $1,092
-
MMBtu
- -
07 2.7314: Reduce ventilation air $713 $832 $88
1,284
kWh
- - $625
-
MMBtu
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $283 $338 $62
893
kWh
$12
-
kW-mo/yr
- - $204 $5
09 3.1161: Eliminate/reduce an operation $1,387 $2,280 $(-3.2)
(-46)
kWh
$(-244.5)
-
kW-mo/yr
- - $1,250 $385
10 2.7142: Utilize higher efficiency lamps and/or ballasts $1,428 $5,369 $658
9,542
kWh
$648
-
kW-mo/yr
- - $119 $3
TOTAL RECOMMENDED $8,485 $10,156 $1,114
16,145
kWh
$552
-
kW-mo/yr
$417 $2,574
-
MMBtu
$1,743 $2,086
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings LPG Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs