| Assessment Year | 2018 |
|---|---|
| Principal Product | Custom Fabricated Plastic Parts |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 23 |
| Plant Area |
31,000
ft2
|
| Annual Production | 394,102
units
|
| Production Hrs. Annual | 4,290
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $9,953 | 144,640 |
kWh
|
$0.069 | |
| Electricity Demand | $9,513 | 934 |
kW-mo/yr
|
$10.19 | |
| Electricity Fees | $4,289 | - |
|
- | |
| LPG | $18,373 | 1,059 |
MMBtu
|
$17.36 | |
| Waste Disposal Costs | |||||
| Water Usage | $806 | 106 |
Tgal
|
$7.60 | |
| TOTAL YEARLY COSTS | $42,934 | ||||
| RECOMMENDED SAVINGS* | $8,485 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $857 | - | - | - | - |
$857
-
MMBtu
|
- | - | |
| 02 | 4.821: Pay bills on time to avoid late fees | $417 | - | - | - | $417 | - | - | - | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $1,176 | $83 | - | - | - | - | - | $1,176 | |
| 04 | 2.8121: Apply for tax-free status for energy purchases | $501 | $83 | - | - | - | - | - | $501 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $631 | $408 |
$309
4,472
kWh
|
$136
-
kW-mo/yr
|
- | - | $170 | $16 | |
| 06 | 2.2136: Install / repair insulation on steam lines | $1,092 | $764 | - | - | - |
$1,092
-
MMBtu
|
- | - | |
| 07 | 2.7314: Reduce ventilation air | $713 | $832 |
$88
1,284
kWh
|
- | - |
$625
-
MMBtu
|
- | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $283 | $338 |
$62
893
kWh
|
$12
-
kW-mo/yr
|
- | - | $204 | $5 | |
| 09 | 3.1161: Eliminate/reduce an operation | $1,387 | $2,280 |
$(-3.2)
(-46)
kWh
|
$(-244.5)
-
kW-mo/yr
|
- | - | $1,250 | $385 | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,428 | $5,369 |
$658
9,542
kWh
|
$648
-
kW-mo/yr
|
- | - | $119 | $3 | |
| TOTAL RECOMMENDED | $8,485 | $10,156 |
$1,114
16,145
kWh
|
$552
-
kW-mo/yr
|
$417 |
$2,574
-
MMBtu
|
$1,743 | $2,086 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | LPG Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs