ITAC Assessment: SU0455
ITAC logo
ITAC Assessment: SU0455
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Electronics Manufacturing Machinery
NAICS 333242: Semiconductor Machinery Manufacturing
SIC 3559: Special Industry Machinery, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 285
Plant Area 248,000
ft2
Annual Production 350
units
Production Hrs. Annual 4,290
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $414,314 8,960,423
kWh
Electricity Demand $135,346 16,465
kW-mo/yr
Electricity Fees $6,240 -
Natural Gas $60,263 12,883
MMBtu
Waste Disposal Costs
Water Usage $10,754 4
Tgal
TOTAL YEARLY COSTS $626,917
RECOMMENDED SAVINGS* $55,248 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $39,925

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4322: Use or replace with energy efficient substitutes $8,432 - $4,968
108,000
kWh
$5,179
-
kW-mo/yr
$(-1,715.0)
-
MMBtu
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $31,032 $51,111 $21,447
466,238
kWh
$7,921
-
kW-mo/yr
- $1,944 $(-280.0)
03 2.7142: Utilize higher efficiency lamps and/or ballasts $461 $1,045 $435
9,463
kWh
$86
-
kW-mo/yr
- $50 $(-110.0)
04 2.6211: Conserve energy by efficient use of vending machines $284 $666 $284
6,168
kWh
- - - -
05 2.7135: Install occupancy sensors $199 $491 $199
4,331
kWh
- - - -
06 2.1224: Replace boiler $14,840 $64,975 - - $14,840
-
MMBtu
- -
TOTAL RECOMMENDED $55,248 $118,288 $27,333
594,200
kWh
$13,186
-
kW-mo/yr
$13,125
-
MMBtu
$1,994 $(-390.0)
TOTAL IMPLEMENTED $39,925 $52,156 $26,850
583,701
kWh
$13,186
-
kW-mo/yr
$(-1,715.0)
-
MMBtu
$1,994 $(-390.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs