Assessment Year 2017
Principal Product Custom Machinery
NAICS 333318: Other Commercial and Service Industry Machinery Manufacturing
SIC 3559: Special Industry Machinery, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 145
Plant Area 148,000
ft2
Annual Production 20
units
Production Hrs. Annual 4,290
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $57,343 1,444,759
kWh
Electricity Demand $44,393 5,198
kW-mo/yr
Electricity Fees $4,358 -
Natural Gas $16,557 3,773
MMBtu
TOTAL YEARLY COSTS $122,651
RECOMMENDED SAVINGS* $13,634 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,325

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $4,841 - - - - - $4,841
02 2.7314: Reduce ventilation air $3,017 $2,941 $1,065
26,604
kWh
- $1,952
-
MMBtu
- -
03 3.1161: Eliminate/reduce an operation $4,869 $5,420 $(-71.0)
(-1,770)
kWh
$(-615.0)
-
kW-mo/yr
- $3,835 $1,720
04 2.7142: Utilize higher efficiency lamps and/or ballasts $484 $810 $227
5,689
kWh
$136
-
kW-mo/yr
- $104 $17
05 2.6211: Conserve energy by efficient use of vending machines $423 $1,480 $423
10,575
kWh
- - - -
TOTAL RECOMMENDED $13,634 $10,651 $1,644
41,098
kWh
$(-479.0)
-
kW-mo/yr
$1,952
-
MMBtu
$3,939 $6,578
TOTAL IMPLEMENTED $5,325 $810 $227
5,689
kWh
$136
-
kW-mo/yr
- $104 $4,858
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs