Assessment Year | 2016 |
---|---|
Principal Product | Treated Lumber |
NAICS | 321114: Wood Preservation |
SIC | 2491: Wood Preserving |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
260,000
ft2
|
Annual Production | 28,700
thousand feet
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $15,746 | 392,773 |
kWh
|
$0.040 |
Electricity Demand | $23,701 | 1,875 |
kW-mo/yr
|
$12.64 |
Electricity Fees | $2,156 | - |
|
- |
Natural Gas | $22,234 | 3,194 |
MMBtu
|
$6.96 |
TOTAL YEARLY COSTS | $63,837 | |||
RECOMMENDED SAVINGS* | $11,945 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,610 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $335 | - |
$685
17,124
kWh
|
- | - | $(-300.0) | $(-50.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $121 | $157 |
$60
1,489
kWh
|
$25
-
kW-mo/yr
|
- | $23 | $13 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,422 | $27,505 |
$1,238
30,961
kWh
|
$5,475
-
kW-mo/yr
|
- | $35 | $(-326.0) | |
04 | 2.1224: Replace boiler | $5,067 | $23,111 | - | - |
$5,067
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $11,945 | $50,773 |
$1,983
49,574
kWh
|
$5,500
-
kW-mo/yr
|
$5,067
-
MMBtu
|
$(-242.0) | $(-363.0) | ||
TOTAL IMPLEMENTED | $11,610 | $50,773 |
$1,298
32,450
kWh
|
$5,500
-
kW-mo/yr
|
$5,067
-
MMBtu
|
$58 | $(-313.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs