ITAC Assessment: SU0411
ITAC logo
ITAC Assessment: SU0411
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Flight Research & Development
NAICS 541712: Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)
SIC 3721: Aircraft
Sales Range $10
M
to 50
M
# of Employees 35
Plant Area 65,465
ft2
Annual Production 10,000
units
Production Hrs. Annual 2,210
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,837 735,654
kWh
Electricity Demand $25,748 2,588
kW-mo/yr
Electricity Fees $3,122 -
Natural Gas $34,079 4,897
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $25,367 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,788

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.4322: Use or replace with energy efficient substitutes $2,414 - $1,160
23,205
kWh
$1,254
-
kW-mo/yr
- - -
02 2.7314: Reduce ventilation air $3,422 $10,350 $480
9,600
kWh
- $2,942
-
MMBtu
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,158 $1,449 $263
5,256
kWh
$72
-
kW-mo/yr
- $613 $210
04 3.1161: Eliminate/reduce an operation $3,627 $6,660 $(-255.0)
(-5,100)
kWh
$(-358.0)
-
kW-mo/yr
- $2,380 $1,860
05 2.6211: Conserve energy by efficient use of vending machines $167 $235 $167
3,347
kWh
- - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $14,579 $45,826 $9,358
187,150
kWh
$6,782
-
kW-mo/yr
- $77 $(-1,638.0)
TOTAL RECOMMENDED $25,367 $64,520 $11,173
223,458
kWh
$7,750
-
kW-mo/yr
$2,942
-
MMBtu
$3,070 $432
TOTAL IMPLEMENTED $10,788 $18,694 $1,815
36,308
kWh
$968
-
kW-mo/yr
$2,942
-
MMBtu
$2,993 $2,070
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs