Assessment Year | 2015 |
---|---|
Principal Product | Industrial Filtration Products |
NAICS | 333999: All Other Miscellaneous General Purpose Machinery Manufacturing |
SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
Sales Range | $10 M to 50M |
# of Employees | 70 |
Plant Area |
74,000
ft2
|
Annual Production | 470,000
pieces
|
Production Hrs. Annual | 4,550
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,192 | 967,240 |
kWh
|
$0.071 |
Electricity Demand | $28,121 | 3,183 |
kW-mo/yr
|
$8.83 |
Electricity Fees | $423 | - |
|
- |
Natural Gas | $26,394 | 3,154 |
MMBtu
|
$8.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,058 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,318 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $6,287 | - | - | - | - | - | $6,287 | |
02 | 2.8114: Change rate schedules or other changes in utility service | $4,921 | - | - | - | - | - | $4,921 | |
03 | 2.4322: Use or replace with energy efficient substitutes | $325 | - |
$192
2,700
kWh
|
$133
-
kW-mo/yr
|
- | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $36 | - |
$15
218
kWh
|
$21
-
kW-mo/yr
|
- | - | - | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,979 | $2,144 |
$3,822
53,836
kWh
|
$3,689
-
kW-mo/yr
|
$(-1,532.0)
-
MMBtu
|
- | - | |
06 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $1,555 | $1,247 |
$1,555
21,903
kWh
|
- | - | - | - | |
07 | 2.7314: Reduce ventilation air | $2,479 | $2,294 |
$520
7,335
kWh
|
- |
$1,959
-
MMBtu
|
- | - | |
08 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $5,273 | $6,721 | - | - |
$5,273
-
MMBtu
|
- | - | |
09 | 2.7135: Install occupancy sensors | $517 | $709 |
$517
7,280
kWh
|
- | - | - | - | |
10 | 2.7243: Improve air circulation with destratification fans / other methods | $3,639 | $5,931 |
$(-517.0)
(-7,276)
kWh
|
$(-88.0)
-
kW-mo/yr
|
$4,244
-
MMBtu
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $443 | $865 |
$236
3,329
kWh
|
$40
-
kW-mo/yr
|
- | $106 | $61 | |
12 | 3.1161: Eliminate/reduce an operation | $1,381 | $3,649 |
$(-107.0)
(-1,500)
kWh
|
$(-318.0)
-
kW-mo/yr
|
- | $882 | $924 | |
13 | 2.6211: Conserve energy by efficient use of vending machines | $176 | $460 |
$176
2,481
kWh
|
- | - | - | - | |
14 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $47 | $163 |
$36
501
kWh
|
$11
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $33,058 | $24,183 |
$6,445
90,807
kWh
|
$3,488
-
kW-mo/yr
|
$9,944
-
MMBtu
|
$988 | $12,193 | ||
TOTAL IMPLEMENTED | $11,318 | $14,927 |
$1,517
21,375
kWh
|
$117
-
kW-mo/yr
|
$9,517
-
MMBtu
|
$106 | $61 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs