ITAC Assessment: SU0397
ITAC logo
ITAC Assessment: SU0397
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2015
Principal Product Metal Fabrication, Machining, Finishing
NAICS 332322: Sheet Metal Work Manufacturing
SIC 3444: Sheet Metal Work
Sales Range $5
M
to 10
M
# of Employees 65
Plant Area 55,000
ft2
Annual Production 1,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $85,552 1,233,357
kWh
Electricity Demand $60,902 4,000
kW-mo/yr
Electricity Fees $12,640 -
Natural Gas $60,475 9,572
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $17,313 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,972

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $630 $552 $201
2,891
kWh
$60
-
kW-mo/yr
- $264 $105
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,191 $1,220 $1,191
17,156
kWh
- - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $14,078 $16,120 $8,078
116,400
kWh
$3,546
-
kW-mo/yr
- $810 $1,644
04 2.7142: Utilize higher efficiency lamps and/or ballasts $390 $573 $271
3,900
kWh
$119
-
kW-mo/yr
- - -
05 3.1161: Eliminate/reduce an operation $584 $1,190 $(-34.0)
(-496)
kWh
$(-548.0)
-
kW-mo/yr
- $495 $671
06 2.4321: Upgrade obsolete equipment $151 $330 $116
1,665
kWh
$35
-
kW-mo/yr
- - -
07 2.6211: Conserve energy by efficient use of vending machines $131 $357 $131
1,883
kWh
- - - -
08 2.7314: Reduce ventilation air $158 $499 $46
656
kWh
- $112
-
MMBtu
- -
TOTAL RECOMMENDED $17,313 $20,841 $10,000
144,055
kWh
$3,212
-
kW-mo/yr
$112
-
MMBtu
$1,569 $2,420
TOTAL IMPLEMENTED $1,972 $2,102 $1,508
21,712
kWh
$95
-
kW-mo/yr
- $264 $105
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs