Assessment Year | 2015 |
---|---|
Principal Product | Bread and Rolls |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 245 |
Plant Area |
153,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 6,400
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $629,243 | 9,021,147 |
kWh
|
$0.070 |
Electricity Demand | $66,415 | 16,153 |
kW-mo/yr
|
$4.11 |
Electricity Fees | $23,072 | - |
|
- |
Natural Gas | $514,748 | 89,027 |
MMBtu
|
$5.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $107,477 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $104,090 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $11,815 | - |
$11,815
168,788
kWh
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,452 | $1,124 |
$9,452
135,030
kWh
|
- | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $3,387 | $210 | - | - |
$3,387
-
MMBtu
|
- | |
04 | 2.2511: Insulate bare equipment | $2,578 | $370 | - | - |
$2,578
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $930 | $1,060 |
$337
4,818
kWh
|
$27
-
kW-mo/yr
|
- | $566 | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $78,891 | $97,500 | - | - |
$78,891
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $424 | $1,010 |
$251
3,584
kWh
|
$28
-
kW-mo/yr
|
- | $145 | |
TOTAL RECOMMENDED | $107,477 | $101,274 |
$21,855
312,220
kWh
|
$55
-
kW-mo/yr
|
$84,856
-
MMBtu
|
$711 | ||
TOTAL IMPLEMENTED | $104,090 | $101,064 |
$21,855
312,220
kWh
|
$55
-
kW-mo/yr
|
$81,469
-
MMBtu
|
$711 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs